Rhythm Turn Lateral Rotation w/True Low Air Loss

Product Code: PHR-RHYT
Regular price Price: $3,494.00
Regular price msrp:$7,451.50
Sale price Price: $3,494.00
Sold out
Shipping calculated at checkout.

Automated Patient Repositioning + Advanced Wound Therapy - Group II Therapeutic System

The Prius Rhythm Turn represents the pinnacle of therapeutic mattress technology, combining automated lateral rotation with True Low Air Loss in a single integrated system. Designed for patients who cannot independently reposition themselves, this revolutionary mattress automatically turns patients up to 40 degrees throughout the day and night—eliminating the need for manual repositioning while simultaneously providing advanced pressure ulcer prevention and treatment.

Key Innovation: Automated lateral rotation dramatically reduces caregiver workload while ensuring consistent, clinically proven repositioning schedules that prevent complications of immobility—including pressure ulcers, pneumonia, and orthostatic intolerance.

Revolutionary Lateral Rotation Technology

Manual patient repositioning is physically demanding for caregivers and often inconsistent due to staffing constraints. The Rhythm Turn solves this critical challenge through automated lateral rotation that works 24 hours a day, slowly and gently turning patients on a customizable schedule.

How Lateral Rotation Works

The mattress contains 18 individual 8-inch air cells that work in coordination to gradually rotate the patient's body from side to side. The rotation is slow, gentle, and nearly silent—patients often sleep through the repositioning cycles without disturbance.

Selectable Turn Angles:

  • 20-Degree Rotation: Gentler turning suitable for fragile patients or initial therapy introduction
  • 40-Degree Rotation: Full therapeutic turning for maximum benefit in preventing pulmonary complications and pressure redistribution

Fully Customizable Timing: Rotation cycles can be adjusted in 5-minute increments from 5 to 95 minutes, allowing clinicians to create standard turning programs or fully customized patterns based on individual patient needs and conditions.

Clinical Benefits of Lateral Rotation

Automated lateral rotation provides critical therapeutic benefits beyond pressure relief:

  • Prevents Pneumonia: Regular position changes promote lung drainage and prevent fluid accumulation that leads to pneumonia
  • Improves Oxygenation: Positional changes enhance pulmonary function and blood oxygenation
  • Reduces Pressure Ulcer Risk: Continuous repositioning prevents sustained pressure on any single area
  • Combats Orthostatic Intolerance: Regular movement helps maintain circulatory system responsiveness
  • Enhances Circulation: Position changes promote blood flow throughout the body
  • Reduces Caregiver Injury: Eliminates repetitive manual lifting and turning that causes back injuries

True Low Air Loss Technology

In addition to lateral rotation, the Rhythm Turn provides True Low Air Loss therapy with an exceptional 1275 LPM airflow capacity—the same advanced technology found in the Rhythm Multi, now combined with automated turning.

Microclimate Management

The powerful airflow system continuously circulates air through the vapor-permeable cover, actively managing heat and moisture to create an optimal healing environment:

  • Keeps skin cool and dry to prevent maceration
  • Reduces heat buildup that damages fragile tissue
  • Manages moisture from perspiration and incontinence
  • Creates ideal conditions for wound healing
  • Maintains therapeutic effectiveness up to 600 lbs

Advanced Control System

User-Friendly Master Control Panel

The intuitive control unit puts complete system management at caregivers' fingertips with clearly labeled, self-explanatory functions:

  • 10 Digital Comfort Settings: Precise firmness control for individualized patient comfort
  • Turn Angle Selection: Independent selection of 20° or 40° rotation
  • Adjustable Rotation Time: 5-95 minutes in 5-minute increments
  • Static Function: Pauses rotation while maintaining Low Air Loss therapy for procedures or patient preference
  • Auto Firm Function: Provides uniform firmness for nursing procedures, transfers, or wound care
  • Visual and Audible Alarms: Low pressure and power failure alerts

Microprocessor Pressure Sensing

Advanced microprocessor technology continuously monitors and adjusts air pressure throughout the rotation cycles, maintaining optimal therapeutic support regardless of patient position. The system automatically compensates for weight shifts during turning, ensuring consistent pressure relief.

Key Features & Clinical Benefits

Eliminates Manual Repositioning

The most significant benefit of the Rhythm Turn is the complete elimination of manual patient repositioning. This revolutionary feature:

  • Reduces caregiver physical strain and injury risk
  • Ensures consistent repositioning schedules 24/7
  • Eliminates staffing concerns related to turning schedules
  • Improves caregiver efficiency and job satisfaction
  • Provides better patient outcomes through consistent care

Ultra-Quiet Operation

Despite the powerful 1275 LPM compressor and continuous rotation mechanism, the Rhythm Turn features double insulation for maximum silent operation. Patients can rest and sleep undisturbed while receiving continuous therapy.

Safety Features

  • Foam Base Backup: Convoluted foam base maintains support during power outages
  • Power Failure Alarm: Audible alert notifies caregivers immediately
  • Quick CPR Deflation: Rapid emergency deflation when needed
  • Integrated Glide Sheet: Built into base cover for safe patient transfers
  • Fire Retardant Cover: Meets clinical safety standards

Clinical-Grade Construction

  • 18 Cell System: Eight-inch air cells provide depth and therapeutic effectiveness
  • Waterproof, Vapor-Permeable Cover: Nylon construction allows air circulation while protecting against fluids
  • 600 lb Weight Capacity: True bariatric support with full therapeutic function
  • Footboard Mounting Rack: Convenient control unit placement

Technical Specifications

Mattress Classification: Group II Therapeutic Support Surface
Mattress Size: 36", 42”, and 48” widths available
Mattress Weight: 28 lbs
Maximum Patient Weight: 600 lbs (bariatric capacity)
Air Cell Construction: 18 cells, 8" height
Foam Base: Convoluted foam for power failure support
Maximum Airflow: 1275 LPM (liters per minute)
Rotation Angles: 20° or 40° (independently selectable)
Rotation Time Range: 5-95 minutes (adjustable in 5-minute increments)
Comfort Levels: 10 digital settings
Cover Material: Nylon (waterproof, vapor-permeable, fire retardant)
Pressure Sensing: Microprocessor-controlled automatic adjustment
Alarm System: Visual and audible low pressure and power failure alerts
Static Mode: Yes (maintains Low Air Loss, pauses rotation)
Auto Firm Function: Yes (for nursing procedures)
CPR Quick Release: Yes
Patient Transfer Feature: Integrated glide sheet in base cover
Electrical: AC 110-120V, 5A max current
Rotation with Head Raised: No

Who Should Use the Rhythm Turn?

This advanced therapeutic system is specifically designed for:

  • Completely immobile patients unable to reposition themselves independently
  • Patients at high risk for pneumonia or respiratory complications from immobility
  • Spinal cord injury patients requiring consistent repositioning
  • Patients with existing pressure ulcers (stages 1-4) needing both rotation and Low Air Loss
  • Post-stroke patients with severe mobility limitations
  • Long-term ICU patients requiring intensive therapeutic intervention
  • Bariatric patients up to 600 lbs where manual turning is difficult or unsafe
  • Facilities with limited staffing for manual repositioning
  • Home care patients with single-caregiver situations where frequent manual turning isn't feasible

Clinical Applications

Pulmonary Care: The lateral rotation is particularly valuable for preventing ventilator-associated pneumonia and other respiratory complications in immobile patients. Regular position changes promote lung drainage and maintain pulmonary function.

Pressure Ulcer Management: The combination of lateral rotation and True Low Air Loss addresses all key factors in pressure ulcer prevention and treatment—pressure redistribution, microclimate management, and continuous repositioning.

Caregiver Burden Reduction: In home care settings with a single caregiver, the Rhythm Turn provides continuous care that would otherwise be impossible. In facilities, it dramatically reduces physical demands on nursing staff.

Bariatric Care: For patients up to 600 lbs, manual repositioning is often unsafe for both patient and caregiver. The Rhythm Turn provides automated, safe turning that maintains dignity while ensuring therapeutic benefit.

Group II Classification & Insurance

The Rhythm Turn qualifies as a Group II Support Surface under Medicare guidelines. This classification is important for:

  • Insurance reimbursement eligibility for advanced therapy
  • Meeting clinical protocols for complex wound care
  • Documentation of appropriate therapeutic intervention
  • Coverage for patients requiring lateral rotation therapy

Consult with your DME provider or insurance representative regarding coverage and documentation requirements for lateral rotation systems.

What's Included

  • Prius Rhythm Turn Lateral Rotation Mattress (36"W × 80"L × 10"H)
  • Master control unit with 1275 LPM compressor
  • Footboard mounting rack for control unit
  • Power cord and connections
  • User manual with clinical protocols
  • Download Owner Manual (PDF)
  • Comprehensive warranty (12 months)

Why Choose All Points Medical?

  • Free Shipping: Ships in 1-2 business days
  • Clinical Expertise: Our specialists understand lateral rotation therapy
  • Authorized Dealer: Factory-backed warranty and technical support
  • Insurance Guidance: We can assist with documentation for reimbursement
  • Installation Support: Guidance available for setup and operation

Important Product Information

Shipping: FREE - Ships in 1-2 business days via ground service

Returns: Medical mattresses cannot be returned due to hygiene regulations

Warranty: 12 months comprehensive coverage

Important Note: The Rhythm Turn cannot rotate when the head of the bed is raised. Rotation is designed for flat or minimally elevated positions. Consult the user manual for complete operational guidelines.

Frequently Asked Questions

Q: How does lateral rotation prevent pneumonia?

A: When patients remain in one position for extended periods, fluid and secretions can pool in the lungs, creating conditions for pneumonia to develop. Lateral rotation continuously changes body position, promoting drainage of pulmonary secretions and preventing fluid accumulation. Studies show automated lateral rotation significantly reduces the incidence of ventilator-associated and aspiration pneumonia in immobile patients.

Q: Will the turning wake my patient up?

A: The Rhythm Turn is designed for slow, gentle, and nearly silent rotation. Most patients sleep through the turning cycles without disturbance. The double-insulated compressor and smooth rotation mechanism ensure quiet operation throughout the night.

Q: Can I adjust how often the patient turns?

A: Yes, completely. You can customize rotation timing from 5 to 95 minutes in 5-minute increments. You can also choose between 20° and 40° turning angles. This flexibility allows you to create standard protocols or fully customize turning schedules based on patient condition, comfort, and clinical needs.

Q: What if I need to pause the turning?

A: The control panel includes a Static Function that pauses rotation while maintaining the True Low Air Loss therapy. This is useful during nursing procedures, wound care, patient meals, or if the patient requests a pause. Simply press the button to resume rotation when ready.

Q: How is this different from the Rhythm Multi?

A: Both systems provide True Low Air Loss with 1275 LPM airflow and similar therapeutic features. The key difference is lateral rotation—the Rhythm Turn automatically repositions patients throughout the day and night, eliminating the need for manual turning. The Rhythm Multi requires manual repositioning but offers pulsation mode instead of rotation.

Q: Does this work for bariatric patients?

A: Yes. The 600 lb weight capacity is genuine therapeutic support, not just structural capacity. The 1275 LPM airflow and rotation mechanism maintain full effectiveness even at maximum weight. For bariatric patients where manual turning is unsafe, this system is invaluable.

Q: Can I use this with the head of the bed raised?

A: No. The Rhythm Turn cannot rotate when the head of the bed is significantly elevated. Rotation is designed for flat or minimally elevated positions. If head elevation is required for medical reasons, consult with your clinical team about whether this system is appropriate.

Q: What happens during a power failure?

A: The convoluted foam base provides continued support and patient safety during power outages. The system produces an audible alarm to alert caregivers immediately to the power issue. The mattress will gradually deflate to the foam base.

Q: How long does setup take?

A: Initial setup takes approximately 20-25 minutes. Place the mattress on the bed frame, mount the control unit on the footboard, connect power, and select your settings. The system will automatically inflate and begin the selected program. The user manual provides detailed setup instructions.

Q: Is this difficult to operate?

A: No. The master control panel is designed to be user-friendly with clearly labeled, self-explanatory controls. Most functions are intuitive, and the system remembers your settings. Training typically takes 10-15 minutes.

Q: How do I clean it?

A: The waterproof cover can be wiped down with standard hospital-grade disinfectants. Follow the manufacturer's cleaning protocols in the user manual to maintain the vapor-permeable properties of the cover.

Q: What if my patient is uncomfortable with the turning?

A: Start with the 20° turning angle and longer cycle times to allow gradual acclimation. Most patients adapt quickly and many find the gentle motion soothing. You can always use the Static Function to pause rotation temporarily if needed. The 10 comfort settings also allow you to adjust firmness for optimal patient comfort.

Need clinical guidance? Lateral rotation therapy represents a significant advancement in immobility management. Our medical equipment specialists can help determine if the Rhythm Turn is appropriate for your patient's specific needs and assist with insurance documentation. Contact us for personalized support.