Brand: Prius
Prius Century Gold Low Air Loss, 2-1 Alternation, Fowler
The Prius Century Gold delivers hospital-grade alternating pressure therapy combined with True Low Air Loss at an accessible price point. 2-1 alternating pressure pattern, 30 LPM on-demand low air loss, Fowler Mode, interchangeable air cells, and air-filled integrated side bolsters. Treats and prevents stage 1–4 pressure ulcers. Available in 36" (500 lb), 42" (700 lb), and 48" (750 lb) widths. Free shipping, ships in 2–3 business days.
Full Description
Full Description
Prius Century Gold Low Air Loss Mattress System
The Century Gold occupies an important middle ground in therapeutic mattress options — more effective than basic alternating pressure systems (adds True Low Air Loss), more affordable than premium high-flow systems. Designed to treat and prevent pressure ulcers at all stages, it delivers essential therapeutic features at a price accessible to home care families and budget-conscious facilities.
2-1 Alternating Pressure
The Century Gold uses 8" air bladders in a 2-1 alternating pressure pattern — continuously redistributing patient weight to prevent sustained pressure on any body area. This therapeutic cycling reduces pressure below the capillary closing threshold, maintaining blood flow to vulnerable tissue.
True Low Air Loss — On Demand
With 30 LPM of airflow, the Century Gold provides genuine low air loss capability — not just alternating pressure with a breathable cover. Air actively circulates through the vapor-permeable cover surface, managing heat and moisture that contribute to skin breakdown. Low air loss can be activated on demand for patients with existing wounds or severe moisture issues.
Fowler Mode
Detects changes in bed frame angle and automatically adjusts mattress pressure to prevent bottoming out when the patient is sitting up — essential for patients who spend significant time with the head of the bed elevated.
Power Outage Protection
Unlike most systems that immediately begin deflating during power loss, the Century Gold's closed system retains air in the cells during brief outages. A 2" foam base provides continued support during extended power loss.
Available Sizes & Weight Capacities
- 36"W × 80"L × 10"H — 500 lb capacity
- 42"W × 80"L × 10"H — 700 lb capacity
- 48"W × 80"L × 10"H — 750 lb capacity
What's Included
- Century Gold mattress with interchangeable air cells
- Digital control unit
- Waterproof, vapor-permeable cover
- Power cord and connections
- User manual and quick reference guide
Product Features
Product Features
Therapeutic Technology
- 2-1 alternating pressure pattern with 8" air bladders — continuous pressure redistribution
- True Low Air Loss — 30 LPM on-demand airflow for microclimate and moisture management
- Fowler Mode — automatically adjusts pressure when head of bed is elevated
- Static mode — constant support during transfers or nursing procedures
- Adjustable cycle timing and comfort settings
Interchangeable Air Cell System
- Individual air cells can be removed and replaced without replacing the entire mattress
- Enables thorough cleaning and disinfection of individual cells
- Reduces replacement costs if a single cell is damaged
- Extends overall mattress lifespan through component-level replacement
Air-Filled Safety Side Bolsters
- Integrated inflatable side bolsters provide fall prevention without separate bed rails
- Soft air-filled barrier — no hard metal edges
- Inflate and deflate with the mattress system
- Do not interfere with transfers or caregiving activities
Construction
- 8" air bladder height — superior patient immersion and body contouring
- 2" foam base — backup support during power outages
- Waterproof, vapor-permeable cover — accepts standard hospital-grade disinfectants
- Whisper-quiet compressor operation
- Expected service life: 5–7 years in home care, 3–5 years in high-use facility settings
Safety & Alarms
- Visual and audible low pressure alarms
- Power failure alarm
- Closed system retains air during brief power outages
Ideal For
- Patients with existing stage 1–4 pressure ulcers needing affordable treatment
- High-risk patients requiring better than basic alternating pressure
- Bariatric patients up to 750 lbs
- Facilities equipping multiple rooms on limited budgets
- Patients with moderate moisture management needs
Specifications
Specifications
| Therapy Type | 2-1 Alternating Pressure + True Low Air Loss |
| Available Sizes | 36", 42", and 48" widths × 80"L × 10"H |
| Weight Capacity — 36" | 500 lbs |
| Weight Capacity — 42" | 700 lbs |
| Weight Capacity — 48" | 750 lbs |
| Air Cell Height | 8 inches |
| Low Air Loss Flow Rate | 30 LPM (on-demand) |
| Fowler Mode | Yes — automatic pressure adjustment for elevated head position |
| Interchangeable Cells | Yes — individual cell replacement |
| Side Bolsters | Air-filled integrated safety bolsters |
| Foam Base | 2" — power failure backup support |
| Cover Material | Waterproof, vapor-permeable |
| Power Requirements | Standard 110V outlet |
| Expected Service Life | 5–7 years home care / 3–5 years facility use |
| Manufacturer | Prius |
Warranty
Warranty
Sale price
Shipping: FREE shipping — ships in 2–3 business days.
Returns: Medical mattresses cannot be returned due to hygiene regulations.